ECOLOGICAL INVERTER type IE1000V2
Destination: Burning destruction of waste from meat processing units (slaughtering waste, specific risk material (MRS), etc.).
Characteristics / Type of incinerator |
U.M. |
IE 1000V2 (discontinuous loading)
|
IE 1000V2 (continuous loading) |
Quantity of the charge |
kg/charge |
3.500…5.000 |
10.000 ... 12.000 |
Time of the charge |
h |
8…10 |
continuously |
The volume and dimensions of the combustion chamber |
m3 |
9,02 |
9,02 |
mm |
Ø =1.880 L = 3.350 |
Ø =1.880 L = 3.350 |
|
Overall dimensions
|
mm |
18.450 4.200 5.200 |
22.000 4.600 4.200 |
Temperature in the combustion chamber |
0 C |
850 |
850 |
Temperature in the post-combustion chamber |
0 C |
1100 |
1100 |
Installed fuel flow (methane / LPG / diesel) |
Nm³/h kg/h |
193,5 / 70,0 197,2 |
193,5 / 70,0 197,2 |
Average fuel consumption (methane / LPG / diesel) |
Nm³/h kg/h |
86,5 / 32,5 88,0 kg/h |
86,5 / 32,5 88,0 |
Waste loading mode |
manual / mechanized in batches |
auto continuously |
|
Gas emission monitoring system |
optional |
optional |
|
Heat Recovery |
optional |
optional |
* The values in the table are quoted for a 30% humidity.
More information:
The heat recovery unit has a power of 1GCal / h, being extremely advantageous as a damping of the investment.
This heat recovery system can be attached to the general heating system, which primarily results in heating or being connected to a thermal plant for preheating water.