1. STEAM STERILIZER, type STAB Horizontal
Designed for use in laboratories for dry steam sterilization of objects that support the working temperatures specific to this type of operation.
Capacities: -Steam Sterilizer type STAB 07 - capacity 7 liters
-Steam Sterilizer type STAB 22 - capacity 22 liters
-Steam Sterilizer type STAB 49 - capacity 49 liters
These Steam Sterilizers are not part of the Class IIA medical device according to European Directive 93/42 / EEC and are used only in laboratories for medium culture inactivation, infected sterilization, etc.
Technical, functional and other features:
- Supply voltage: 220 V / 50 Hz;
- The power consumed in the hold-up phase (at 134oC): 45% of the Pmax. ;
- Range of working temperatures: (121..135) oC;
- Precision temperature at stabilization (at 132 oC): 2,5 oC;
- The device is equipped with a temperature-time controller, with a microprocessor;
- Temperature control and regulation is done by the microprocessor;
- Measuring resolution: ± 0,1 oC;
- Display resolution: ± 1 oC;
- Automatic steam purge;
- At the end of the cycle, the water is automatically removed from the enclosure;
- Acoustic warning at the end of the cycle;
- Included accessories: condensate drain and stainless steel basket;
The Steam Sterilizer is the device that performs the operation by which all microorganisms attached on contaminated objects, including bacterial spores, are destroyed. The result of which is the sterility state when coming into contact with human body tissues or penetrates tissues including the normally sterile vascular system. Examples: surgical instruments, dental instruments, suture material, birth attendance kits, operating room staff, operating fields, swabs and buffers, drainage tubes, implants, needles and syringes, cardiac and urinary catheters, for hemodialysis, all intravascular devices, flexible or rigid endoscopes used in invasive procedures, endoscopy-associated biopsy equipment, acupuncture needles, those used in neurology; these devices must be sterilized. Steam Sterilizers must comply with Community legislation on reforters in Medical Devices.
Steam Sterilizer type |
STAB C07 |
STAB C22 /C22 V |
STAB C49 / C49V |
Working position |
Orizontal |
Orizontal / Vertical |
Orizontal / Vertical |
Steam Sterilizer volume [l] |
7 |
22 |
49 / 49,5 |
Chamber size[mm] |
Ø160 x 365 |
Ø 220 x 450 Ø 240 x 500 |
Ø 350 x 520 Ø 300x 700 |
The installed power [W] |
1500 |
2300/2000 |
3000 |
Supply voltage |
220 V / 50 Hz |
220 V / 50 Hz |
220 V / 50Hz |
Overall dimensions [mm] |
350 x 525 x 235 |
450 x 750 x 330 480 x 480 x 1120 |
715 x 900 x 600 510 x 510 x 1250 |
The amount of water needed / cycle [l] |
0,5 |
1,5/2,0 |
3,0 |
Operating temperature range [oC] |
121..1 |
121.. 138 |
121.. 138 |